He also earned a master's degree engineering from the same university and an MBA degree from the Hong Kong University of Science and Technology. Cheng has completed arc flash calculations (ac and dc) for major utilities and corporations across North America and was involved in the arc flash testing for OPG, IEEE and EPRI.

Shanghai C&G Safety Co., Ltd. is a professional industrial flame resistant uniform solution and electric arc flash protection provider based in Pudong District of Shanghai, China.As a strategic partner of well-known fiber and fabric suppliers, from fabric development, and garment design to marketing and sales, we work closely with our fiber and ...

arc flash testing and research, and provides a variety of testing on flame and arc resistant ... to test for our clients at Kinectrics in Toronto. Check our schedule for dates. Third-party, ...

o Alternating Current (AC) Table 130.7(C)(15)(A)(b) o Direct Current (DC) Table 130.7(C)(15)(B) - Identify the PPE Category and need for V- rated gloves and tools associated with that task - Select Arc Rated clothing and PPE associated with that level PPE Selector - Selection

Kinectrics has almost a decade of experience in applying these techniques and, during that time, the company has tested more than 1,715 km of cable operating at 66 kV and up. The tests have covered 307 individual phases, 614 terminations and 2,654 joints and it is in interesting to note that failure rates have remained substantially constant ...

Arc Flash study. The Electrical Consultant/Contractor shall perform a study for the purposes of estimating worst case available short circuit current values and Arc Flash incident energy. The final study will be generated based on the final electrical equipment submittals and the final pulled conductor lengths for all feeders.

“Arc Flash Calculations for Exposures to DC Systems,” Doan, D.R., IEEE IAS ... NFPA 70E® Approach to Considering DC Hazards DC ELECTRICAL HAZARD ANALYSIS Shock Hazard Analysis . HOYDAR- BUCK, INC. Adder 15.1 kV NFPA 70E® Approach to Considering DC Hazards DC ELECTRICAL HAZARD ANALYSIS TABLE 130.4(C)(b) ...

Kinectrics has conducted thousands of AC and DC arc flash tests at its High Current Laboratory for corporations across North America and hence, has unmatched understanding of the limitations of each analysis tool and methodology. The vast majority of PPE fabrics used in North America are tested at Kinectrics' high current facility.

-2002IEEE Guide for Performing Arc-Flash Hazard Calculations SponsorPetroleum and ... Crouse-HindsDuPont NomexKinectrics Inc.U. S. Navy NAVSEA CommandSquare D ...

Kinectrics has done testing on single phase arcs and is in fact the basis for NESC arc flash tables. I believe work was originally done by Ontario Hydro. It appears that OSHA will be recognizing this work as an accetable method in the future. The range of testing does include low voltage. I do not see anyone referencing this work or software.

What Are the Types of Incident Energies?In an arc flash hazard analysis there are two distinct values of incident energies to be considered depending on the type of equipment and if the equipment has a main breaker. Switchgear, switchboards, and panelboards (to name a few) with main breakers will have line-side incident energy values and load-side incident energy values.